RG860 Trunk Amplifier/BDA
  • RG860 Trunk Amplifier/BDA

RG860

RG860 is two-way signal amplification enhancement equipment. It mainly provide two-way signal amplification for terminals and base station .It extends the base station signal in the building, underground construction, tunnels, airports, etc. .
  • 产品特点
  • 规格参数
  • 产品应用
  • 下载中心


    Key Function Features

    The newest data platform control

    Conveniently configure key indicators, increasing the service efficiency of the user

    Adopts numerical control gain adjustment

    The gain rang up to 30 dB, the full width meets user request

    ALC technology

    The output level can be adjusted continuously and automatically

    Highly linear power amplification

    Effectively restrain intermodulation and hum & noise

    Guaranteed isolation

    Excellent RX and TX isolation, convenient installation could be assured.

    Real-time remote monitoring

    Through the network platform, can real-time usage of equipment in real time remote monitoring and management


    Key Structure Features

    Strong and durable

    Fully according to the American military standard, with functions of dust-proof, moisture-proof, waterproof, protection grade reaches IP65

    Modular design

    Fully adopt the modular design, convenient product maintenance and increasing products stability

    Double port design

    Double connection design, easy construct, Ensure the installation neat and beautiful

    Unique way of heat dissipation

    With good heat dissipation materials and unique natural cooling method ensure the working life is longer.

    Parted RX and TX design

    Parted application of RX and TX circuit design, convenient indoor and outdoor coverage


    General
    Frequency Up/Down:400~470MHz
    (Up-down space 10MHz)
    Bandwidth 5MHz(Customized Frequency )
    Power Supply AC220V±15%
    Power Dissipation ≤150W
    Heat-dissipating Natural
    Monitor Type Local and Remote
    Connection Type N/F
    Measure(HXWXD) 533×350×205mm
    Weight 24.10Kg
    Environmental
    Working Temperature -30℃~60℃
    Storage Temperature -40℃~85℃
    ESD ±8kV(Contact Discharge)
    ±8kV(Air Discharge)
    Dust&Water Intrusion IP65 Standard
    Technical
    Power  Output Down:33±3dBm 37±3dBm(Optional)
    Up:-5dBm
    Maximum Gain 45±3dB
    Gain Regulating Range ≥30dB
    Gain Regulating Step width ≤1dB
    Gain Regulating Error 0~20dB overall error≤±1dB
    ≥20dB overall error≤±1.5dB
    Frequency Error ≤Input Frequency at±5*10-8
    Passband Fluctuation ≤1dB(Peak)
    Noise Figure ≤5dB
    VSWR ≤2
    Time Delay ≤1.0μs
    Spurious Emission(In-band) ≤-15dBm@30KHz
    fo±1MHz
    Spurious Emission(Out-of-brand)
    (Deviating from the working frequency band of 10 MHZ)
    9KHz~150KHz:-36dBm@1KHz
    150KHz~30KHz:-36dBm@10KHz
    30MHz~1GHz:-36dBm@100KHz
    1GHz~12.75GHz:-30dBm@1MHz
    Intermodulation Attenuation
    (In-brand)
    ≤-45dBc@30KHz
    Intermodulation Attenuation
    ((Out-of-brand)
    9KHz~1GHz≤:-36dBm@30KHz
    1GHz~12.75GHz≤-30dBm@100MHz
    Rejection(Out-of-brand) Deviating from the assigned frequency≥10MHz:
    ≤-30dBc
    Deviating from the working frequency band edge≥20MHz:
    ≤-50dBc

    Application

    Dock signal coverage

    Airport signal coverage

    Tunnel signal extension

    Building signal coverage

    Basement signal coverage



    Application Cases

    Airport signal coverage

    The airport usually installs the trunking base station system based on large area and the infrastructure. If the trunk amplifier is installed in the trunking base station system, it can enhance the signal coverage of the trunking system and guarantee the quality of the call, reduce the number of base stations, save the cost of system.

    Tunnel signal extension coverage

    Tunnel is usually a tubular structure, and it is long and narrow. It mainly located in the mountain and the mountain produces blocking signal and the tunnel is signal blind area. To install the trunk amplifier, can enhance the signal and ensure communication without blind area.

    Building signal coverage

    Because short distance between the dense buildings and different floors, the transmission signal is fading fast between buildings, and environmental reasons, such as electromagnetic dry approach and many other factors led to the poor call quality between buildings. RG860 could selectively amplify the signal, and ensure the purity of forward signal and improve the call quality.

    Basement signal coverage

    Communication signal will have loss through the transmission, penetration also will be declining, and the arrived in the basement of the signal is very weak. Most of the low-rise buildings, the basement is signal blind area coming with poor call quality. Adopts the trunk amplifier and introduce signal into the basement can significantly improve the call quality



    正在建设中,敬请期待~